| Sign In | Join Free | My chinacomputerparts.com | 
 | 
Brand Name : GENY
Model Number : YC99T-3C/5C
Certification : ISO, CE
Place of Origin : China
MOQ : 1
Price : negotiate rates
Payment Terms : T/T, L/C, D/P, T/T
Supply Ability : 5 sets / 1 months
Delivery Time : 6~8weeks
Packaging Details : Plywood cases
Material : Aluminum Alloy
Meter Position : 3
Accuracy : 0.05
AC Voltage Output Range : 57.7V,100V, 220V, 380V
Frequency Output : 45Hz – 70Hz
Storage Environment : -20℃~50℃
Environment Condition : 20℃ ~ 30℃ relative humidity
| Model No. | YC99T-3C | 
| Meter Position / Accuracy | 3 / 0.05 | 
| AC Voltage output | |
| Range | 57.7V,100V, 220V, 380V,660 | 
| Adjustment Range | (0-120)%RG (RG is Range) | 
| Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG | 
| Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) | 
| Distortion | ≤0.2% (Non capacitive load) | 
| Max Output load | 20VA/phase | 
| Measurement Accuracy | ±0.05%RG(0.05cl), ±0.1%RG(0.1cl) | 
| AC Current output | |
| Range | 0.05A,0.2A,1A,5A,16.67A,50A | 
| Adjust Range | (0-120)%RG (RG is Range) | 
| Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG | 
| Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) | 
| Distortion | ≤0.2% (Non capacitive load) | 
| Max Output load | 50VA(50A range) | 
| Measurement Accuracy | ±0.05%RG(0.05cl), ±0.1%RG(0.1cl) | 
| Power output | |
| Stability | 0.01%/2min(0.05cl), 0.02%/2min(0.1cl) | 
| Active, Reactive power accuracy | ±0.05%RG | 
| Phase output | |
| Output adjusting range | 0 ~ 359.99° | 
| Output adjusting power | 10°,1°,0.1°,0.01°optional | 
| Resolution | 0.01. | 
| Measurement accuracy | ±0.05. | 
| Power factor output | |
| Adjusting range | -1~0~+1 | 
| Measuring resolution | 0.0001 | 
| Measurement accuracy | ±0.0005 | 
| Frequency output | |
| Adjusting range | 40Hz – 70Hz | 
| Output adjusting resolution | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional | 
| Resolution | 0.001Hz | 
| Accuracy | ±0.002Hz | 
| Harmonic setting | |
| Harmonic order | 2nd~63rd | 
| Harmonic amplitude | 0~40% | 
| Harmonic angle | 0 °~359.00° | 
| Harmonic set error | 2nd ~ 31st :≤±0.1%, 32nd~63rd : ≤±0.2% | 
| Energy error measurement | |
| Active energy basic error limit | ±0.05%RD(voltage30V~660V,current0.02A~60A,PF≥0.5) | 
| Reactive energy basic error limit | ±0.1%RD(voltage30V~660V,current0.02A~60A,PF≥0.5) | 
| Standard crystal | |
| Frequency accuracy | ±0.5ppm (leave factory@25℃) | 
| Frequency stability | ±0.1ppm,-20℃~+70℃ | 
| Energy pulse input | |
| Number of energy pulse input | 3 channels active, 3 channels reactive | 
| General parameters | |
| Power supply | AC220V±15% or 110V±15% | 
| Frequency | 50Hz~60Hz | 
| Consumption | 60VA~1000VA | 
| Environment condition | 20℃ ~ 30℃,relative humidity≤85% | 
| Storage environment | -20℃~50℃ | 
| Size & Weight | 600mm(L)X400mm(W) X266mm(H), 30kg | 
| Model No. | YC99T-5C | 
| Meter Position / Accuracy | 3 / 0.05cl | 
| AC Voltage output | |
| Range | 57.7V,100V, 220V, 380V | 
| Adjustment Range | (0-120)%RG (RG is Range) | 
| Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG | 
| Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) | 
| Distortion | ≤0.2% (resistance load) | 
| Max Output load | 20VA/phase | 
| Measurement Accuracy | ±0.05%RG(0.05cl), ±0.1%RG(0.1cl) | 
| AC Current output | |
| Range | 0.05A,0.2A,1A,5A,20A,100A | 
| Adjust Range | (0-120)%RG (RG is Range) | 
| Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG(optional) | 
| Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) | 
| Distortion | ≤0.2% (Non capacitive load) | 
| Max Output load | 100VA(100A range) | 
| Measurement Accuracy | ±0.05%RG(0.05cl), ±0.1%RG(0.1cl) | 
| Power output | |
| Stability | 0.01%/2min(0.05cl), 0.02%/2min(0.1cl) | 
| Active, Reactive power accuracy | ±0.05%RG | 
| Phase output | |
| Output adjusting range | 0 ~ 359.99° | 
| Output adjusting power | 10°,1°,0.1°,0.01°optional | 
| Resolution | 0.01. | 
| Measurement accuracy | ±0.05. | 
| Power factor output | |
| Adjusting range | -1~0~+1 | 
| Measuring resolution | 0.0001 | 
| Measurement accuracy | ±0.0005 | 
| Frequency output | |
| Adjusting range | 45Hz – 70Hz | 
| Output adjusting resolution | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz | 
| Resolution | 0.001Hz | 
| Accuracy | ±0.002Hz | 
| Harmonic setting | |
| Harmonic order | 2nd~63rd | 
| Harmonic amplitude | 0~40% | 
| Harmonic angle | 0 °~359.99° | 
| Harmonic set error | 2nd ~ 31st :≤±0.1%, 32nd~63rd : ≤±0.2% | 
| Energy error measurement | |
| Active energy basic error limit | ±0.05%RD(voltage30V~380V,current0.02A~120A,PF≥0.5) | 
| Reactive energy basic error limit | ±0.1%RD(voltage30V~380V,current0.02A~120A,PF≥0.5) | 
| Standard crystal | |
| Frequency accuracy | ±0.5ppm (leave factory@25℃) | 
| Frequency stability | ±0.1ppm,-20℃~+70℃ | 
| Energy pulse input | |
| Number of energy pulse input | 3 channels active, 3 channels reactive | 
| General parameters | |
| Power supply | AC220V±15% or 110V%15% | 
| Frequency | 50Hz~60Hz | 
| Consumption | 60VA~1000VA | 
| Environment condition | 20℃ ~ 30℃,relative humidity≤85% | 
| Storage environment | -20℃~50℃ | 
| Size & Weight | 600mm(L)X400mm(W) X266mm(H), 48kg | 


|   | 
| 45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities Images | 
 Portable Meter Test System For AC Voltage Current Power Phase And Frequency
                                                                                        
                                                        
                        
                        
                        
                                                            Portable Meter Test System For AC Voltage Current Power Phase And Frequency
                                                    
                        
                     Portable Meter Test System with High Accuracy Current and Voltage Source
                                                                                    
                        
                        
                        
                                                            Portable Meter Test System with High Accuracy Current and Voltage Source
                                                    
                        
                     Portable Meter Test System For Three Phase Energy Meters With Automatic
                                                                                    
                        
                        
                        
                                                            Portable Meter Test System For Three Phase Energy Meters With Automatic
                                                    
                        
                     0.05 Accuracy Portable Meter Test Equipment Three Phase Test Meter Calibration
                                                                                        
                                                        
                        
                        
                        
                                                            0.05 Accuracy Portable Meter Test Equipment Three Phase Test Meter Calibration
                                                    
                        
                     GENY Portable Energy Meter Test Equipment YC99B Energy Meter Calibration On
                                                                                    
                        
                        
                        
                                                            GENY Portable Energy Meter Test Equipment YC99B Energy Meter Calibration On
                                                    
                        
                     Portable Meter Test System YC92B Single Phase Energy Meter Test Bench
                                                                                    
                        
                        
                        
                                                            Portable Meter Test System YC92B Single Phase Energy Meter Test Bench
                                                    
                        
                     Portable Energy Meter Test Bench
                                                                                        
                                                        
                        
                        
                        
                                                            Portable Energy Meter Test Bench
                                                    
                        
                     Accuracy 0.05 Energy Meter Test Equipment 3 Position Test Electric Meter
                                                                                    
                        
                        
                        
                                                            Accuracy 0.05 Energy Meter Test Equipment 3 Position Test Electric Meter
                                                    
                        
                     YC1022C Universal Calibration Device for Electrical Measuring Instruments V1.05
                                                                                    
                        
                        
                        
                                                            YC1022C Universal Calibration Device for Electrical Measuring Instruments V1.05
                                                    
                        
                     High-Performance Portable Meter Test System for Precise AC/DC Voltage and
                                                                                    
                        
                        
                        
                                                            High-Performance Portable Meter Test System for Precise AC/DC Voltage and